millipore,密理博,MSCRMAG-42K,MILLIPLEX MAP Mouse Soluble Cytokine Receptor Magnetic Bead Panel - Immunology Multiplex Assay

产品名称:
MILLIPLEX MAP Mouse Soluble Cytokine Receptor Magnetic Bead Panel - Immunology Multiplex Assay
产品型号:
MSCRMAG-42K
产品描述:

产品介绍

millipore,密理博,MSCRMAG-42K,MILLIPLEX MAP Mouse Soluble Cytokine Receptor Magnetic Bead Panel - Immunology Multiplex Assay
millipore,密理博,MSCRMAG-42K,MILLIPLEX MAP Mouse Soluble Cytokine Receptor Magnetic Bead Panel - Immunology Multiplex Assay

Description
Catalogue NumberMSCRMAG-42K
Trade Name
  • MILLIPLEX
DescriptionMILLIPLEX MAP Mouse Soluble Cytokine Receptor Magnetic Bead Panel - Immunology Multiplex Assay
OverviewThe MILLIPLEX MAP Mouse Soluble Cytokine Receptor Panel contains 13 metastasis biomarkers that have also been identified in a variety of therapeutic areas. Coupled with the Luminex® xMAP® platform in magnetic bead format, this panel enables researchers to focus on discovery with the advantage of simultaneous quantitative multiplex detection leading to speed and sensitivity.
Background InformationCytokine receptors constitute an integral part of the cytokine biology. Like cytokines, cytokine receptors are involved in normal physiological and pathological processes of almost all disease states. Soluble cytokine receptors naturally arise from genes encoding membrane-bound receptors or are direct derivatives of the receptors themselves. The discovery that soluble cytokine receptors are involved in regulating excessive inflammatory responses and modulating immune events has stimulated significant research interest in their potential role as immunotherapeutic agents. Many of these soluble cytokine receptors have the ability to inhibit the binding and biological activity of their cytokine ligands, making them very specific cytokine antagonists.
Product Information
Detection methodLuminex xMAP
ConfigurationDesign your multiplex kit by choosing available analytes within this panel.
Precision, %
  • Intra-assay: < 7
  • Inter-assay: < 12
Panel TypeMAGNETIC Cytokines/Chemokines
Quality LevelMQ200
Applications
ApplicationSimultaneously analyze multiple cytokine and chemokine biomarkers with Bead-Based Multiplex Assays using the Luminex technology, in mouse serum, plasma and cell culture samples.
Key Applications
  • Multiplexing
Application Notes• An overnight incubation assay is recommended.
• This assay requires 25 μL of 1:5 diluted serum and plasma or tissue/cell culture supernatant
Biological Information
Species Reactivity
  • Mouse
Analytes Available
  • sCD30 (sTNFRSF8)
  • sgp130
  • sIL-1RI (sCD121a)
  • sIL-1RII (sCD121b)
  • sIL-2Rα (sCD25)
  • sIL-4R (sCD124)
  • sIL-6R (sCD126)
  • sRAGE
  • sTNFRI (sTNFRSF1A)
  • sTNFRII (sTNFRSF1B)
  • sVEGFR1 (sFlt-1)
  • sVEGFR2 (sFlk-1)
  • sVEGFR3 (sFlt-4)
Assay PanelEverything you need in a single kit.
Accuracy
  • 89% - 98 %
Physicochemical Information
Sensitivity
  • Refer to kit protocol for sensitivities of individual biomarkers.
Linearity of DilutionContact Technical Service for this information
Standard Curve Range
  • sCD30, sgp130, sIL-6R, sRAGE, sVEGFR1, sVEGFR2, sVEGFR3: 24.4 – 100,000 pg/mL
  • sIL-1RI, sIL-1RII, sIL-2Rα, sIL-4R, sTNFRII: 12.2 – 50,000 pg/mL
  • sTNFRI: 4.9 – 20,000 pg/mL
Product Usage Statements
Usage Statement
  • Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
Packaging Information
Material Size96-well plate
上一条millipore,密理博,MPXDF-4PK,MAGPIX Drive Fluid, 4 pack
下一条millipore,密理博,MSHMAG-21K,MILLIPLEX MAP Multi-Species Hormone Magnetic Bead Panel

相关产品


访客留言

15900658720
18017322602