millipore,密理博,CKT2MAG-97K,MILLIPLEX MAP Canine Kidney Toxicity Panel 2 - Toxicity Multiplex Assay

产品名称:
MILLIPLEX MAP Canine Kidney Toxicity Panel 2 - Toxicity Multiplex Assay
产品型号:
CKT2MAG-97K
产品描述:

产品介绍

millipore,密理博,CKT2MAG-97K,MILLIPLEX MAP Canine Kidney Toxicity Panel 2 - Toxicity Multiplex Assay
millipore,密理博,CKT2MAG-97K,MILLIPLEX MAP Canine Kidney Toxicity Panel 2 - Toxicity Multiplex Assay

重要规格表

Analytes AvailableSpecies ReactivityKey ApplicationsDetection Methods
Albumin, β-2-Microglobulin, Trefoil Factor 3 (TFF-3), Retinol Binding Protein 4 (RBP4) Ca Mplex Luminex xMAP
Description
Catalogue NumberCKT2MAG-97K
Trade Name
  • MILLIPLEX
DescriptionMILLIPLEX® MAP Canine Kidney Toxicity Panel 2 - Toxicity Multiplex Assay
OverviewThe MILLIPLEX® MAP Canine Kidney Toxicity Panel 2 contains all the components necessary to measure the following four biomarkers in any combination using Luminex® xMAP® technology: Albumin, β-2-microglobulin (B2M), Trefoil Factor 3 (TFF-3), Retinol Binding Protein 4 (RBP4). The kit uses a 96-well format, contains a lyophilized standard cocktail, two quality controls and can measure up to 38 urine samples in duplicate.
Background InformationAs one of the leading causes of drug candidate attrition, toxicity research is receiving more attention, especially in the search of sensitive, organ-specific toxicity biomarkers.

In pharmaceutical and chemical industries, renal function is routinely assessed during toxicity evaluations. The importance of the kidney as a central detoxification organ leads to a high exposure of renal tissue to drugs, reactive metabolites, and environmental compounds. Traditional markers for assessing renal toxicity, such as blood urea nitrogen (BUN) and serum creatinine, are insensitive and non-specific. For improved, non-invasive detection of acute nephrotoxicity, a panel of novel urinary kidney biomarkers has been identified and validated for preclinical studies in relevant animal species.

EMD millipore provides a valuable research assay to investigate multiple biomarkers of kidney injury in canine urine samples using the Luminex xMAP® instrument platform. The MILLIPLEX® MAP Canine Kidney Toxicity Panel 2 offers simultaneous analysis of any combination of the following analytes: Albumin*, β-2-microglobulin (B2M)*, Trefoil Factor 3 (TFF-3)*, Retinol Binding Protein 4 (RBP4)*.

*Urinary albumin, B2M, TFF-3 and RBP4 are biomarkers listed in the Predictive Safety Testing Consortium (PSTC) project pipeline which have a strong translational role in drug safety testing.
Product Information
Components
  • Canine Kidney Toxicity Panel 2 Standard, 1 vial, lyophilized
  • Canine Kidney Toxicity Panel 2 Control 1, 1 vial, lyophilized
  • Canine Kidney Toxicity Panel 2 Control 2, 1 vial, lyophilized
  • Assay Buffer, 2 bottles, 30 mL
  • Wash Buffer, 10X (0.05% Proclin), 2 bottlesl, 30 mL
  • Canine Kidney Toxicity Panel 2 Detection Antibodies, 1 bottle, 5.5 mL
  • Streptavidin-Phycoerythrin, 1 bottle, 5.5 mL
  • Mixing Bottle, 1 bottle
  • Sample Plate, 96 well format, 1 plate
  • 2 Foil Plate Sealers
Detection methodLuminex xMAP
ConfigurationDesign your multiplex kit by choosing available analytes within this panel.
Precision, %
  • Inter-assay: <15
  • Intra-assay: <10
Panel TypeMAGNETIC Toxicity
Quality LevelMQ200
Applications
ApplicationThe analytes available for this multiplex kit are: Albumin, β-2-microglobulin (B2M), Trefoil Factor 3 (TFF-3), Retinol Binding Protein 4 (RBP4)
Key Applications
  • Multiplexing
Application Notes• Customers should determine the optimal dilution factor for their samples. Our recommendations are based on urine samples from normal subjects.
• This assay requires 25 µL of 1:500 diluted urine sample per well in kit Assay Buffer (please dilute per protocol instructions).
• This is a 2 hour assay.
Biological Information
SpecificityApproximately 5% cross-reactivity may be observed between B2M beads and TFF-3 protein. No other significant cross-reactivity was observed for other analytes in this panel.
Species Reactivity
  • Canine
Analytes Available
  • Albumin
  • β-2-Microglobulin
  • Trefoil Factor 3 (TFF-3)
  • Retinol Binding Protein 4 (RBP4)
Assay PanelEverything you need in a single kit.
Cross ReactivityApproximately 5% cross-reactivity may be observed between B2M beads and TFF-3 protein. No other significant cross-reactivity was observed for other analytes in this panel.
Accuracy
  • 96% - 102%
Physicochemical Information
Sensitivity
  • Albumin: 12.48 ng/mL (MinDC +2SD)
  • All other analytes: 0.016 - 0.026 ng/mL (MinDC +2SD)
  • See kit protocol for individual analyte sensitivities.
Linearity of DilutionContact technical support for this information.
Standard Curve Range
  • Albumin: 12.21 – 50,000 ng/mL
  • B2M: 0.02 – 100 ng/mL
  • TFF-3: 0.02 – 100 ng/mL
  • RBP4: 0.01 – 50 ng/mL
Product Usage Statements
Usage Statement
  • Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
Storage and Shipping Information
Storage ConditionsRecommended storage for kit components is 2 - 8°C.
Packaging Information
Material Size96-well plate
上一条millipore,密理博,CKT1MAG-97K,MILLIPLEX MAP Canine Kidney Toxicity Expanded Magnetic Bead Panel 1, CKT1MAG-97K