millipore,
密理博,APOMAG-62K,MILLIPLEX MAP Human Apolipoprotein Magnetic Bead Panel - Cardiovascular Disease Multiplex Assay
重要规格表
| Analytes Available | Species Reactivity | Key Applications | Detection Methods |
| Apo AI, Apo AII, Apo B, Apo CII, Apo CIII, Apo E
| H
| Mplex
| Luminex xMAP
|
| Description
|
| Catalogue Number | APOMAG-62K |
| Trade Name |
|
| Description | MILLIPLEX MAP Human Apolipoprotein Magnetic Bead Panel - Cardiovascular Disease Multiplex Assay |
| Background Information | Metabolic Syndrome has received increased attention from the medical community with more and more cases of obesity, type 2 diabetes and cardiovascular diseases being described and studied. To help researchers better understand the complexities of metabolic syndrome and cardiovascular disease, millipore is pleased to offer the Human Apolipoprotein magnetic bead panel that will measure any combination of 6 analytes, including Apo AI, Apo AII, Apo B, Apo CII, Apo C III and Apo E. |
| Product Information
|
| Detection method | Luminex xMAP |
| Configuration | Design your multiplex kit by choosing available analytes within this panel. |
| Precision, % |
- Inter-assay: <20
- Intra-assay: <10
|
| Panel Type | MAGNETIC Cardiovascular |
| Quality Level | MQ200
|
| Applications
|
| Application | This MILLIPLEX MAP Human Apolipoprotein Magnetic Panel is a Cardiovascular Disease multiplex assay. The analytes available for this multiplex kit are: Apo AI, Apo AII, Apo B, Apo CII, Apo CIII, Apo E. |
| Key Applications |
|
| Application Notes | • This kit may be used for the analysis of Human Apolipoproteins in Human serum, plasma, tissue culture supernatant or other biological samples • Sample dilutions for serum and plasma are recommended at 1: 4,000 • The assay can be performed in less than 3 hours |
| Biological Information
|
| Species Reactivity |
|
| Analytes Available |
- Apo AI
- Apo AII
- Apo B
- Apo CII
- Apo CIII
- Apo E
|
| Cross Reactivity | To test cross-reactivity among the assays in the panel, individual apolipoprotein standard was prepared at a concentration 4 times greater than the highest concentration in the calibration curve and tested in the 6-plex assays with multiplexed beads containing immobilized capture antibodies and individual detection antibodies. There was negligible cross-reactivity within the panel. |
| Accuracy |
- Apo AI 86%
- Apo AII 91%
- Apo B 92%
- Apo CII 92%
- Apo CIII 89%
- Apo E 85%
|
| Physicochemical Information
|
| Sensitivity |
- Apo AI 1.48 ng/mL
- Apo AII 1.00 ng/mL
- Apo B 4.84 ng/mL
- Apo CII 1.22 ng/mL
- Apo CIII 1.71 ng/mL
- Apo E 1.42 ng/mL
|
| Linearity of Dilution | Contact technical support for this information. |
| Standard Curve Range |
- Refer to the kit protocol for details.
|
| Product Usage Statements
|
| Usage Statement |
- Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
|
| Packaging Information
|
| Material Size | 96-well plate |