密理博,03-0092-00,SMC Human Cardiac Troponin I (cTnI)IMMUNOASSAY KIT
重要规格表
| Analytes Available | Species Reactivity | Key Applications |
| Cardiac Troponin I
| H, Mk, R, Ca, Gp
| Single Molecule Counting (SMC™)
|
| Description
|
| Catalogue Number | 03-0092-00 |
| Trade Name |
|
| Description | SMC™ Human Cardiac Troponin I (cTnI) IMMUNOASSAY KIT |
| Overview | The SMC™ Human cTnI Immunoassay Kit contains all reagents required to perform the assay. This assay takes advantage of a standard immunoassay workflow configured in a standard plate format. Assay protocols are similar to existing sandwich ELISA methods with two key differences: 1) Elution buffer disrupts the sandwich, separating the labeled detection antibody for quantification. 2) The SMC™ immunoassay system detects analytes using Single Molecule Counting (SMC™) technology. |
| Background Information | Cardiac Troponin-I (cTnI) is specific to cardiomyocytes and is released into the bloodstream following heart damage. Extensive studies have shown that cTnI is slowly released from damaged cardiomyocytes. This has allowed cTnI to become widely accepted in preclinical and clinical drug development settings as an indicator of myocardial damage and hence, heart damage.The high sensitivity of the research grade Erenna cTnI assay uniquely provides utility across multiple species and matrices. |
| Product Information
|
| Components |
- cTnI Coated Beads
- Standard Diluent
- cTnI Detection Antibody
- Assay Buffer
- cTnI Standard
- 10X Wash Buffer
- Elution Buffer B
- Buffer D
- SMC™ Human cTnI Immunoassay Kit Instructions
|
| Precision, % |
- Low-end CV% Range: 0-20%
- Low-end CV% Average: 12%
|
| Quality Level | MQ200
|
| Applications
|
| Application | The sensitivity of the Single Molecule Counting (SMC™) technology gives the SMC™ Cardiac Troponin (cTnI) Immunoassay Kit unparalleled performance in the quantification of cTnI in human EDTA plasma and serum. |
| Key Applications |
- Single Molecule Counting (SMC™)
|
| Biological Information
|
| Species Reactivity |
- Human
- Monkey
- Rat
- Canine
- Guinea Pig
|
| Analytes Available |
|
| Accuracy |
- Minimum of 10 samples spiked with acceptable recovery between 80-120%.
|
| Physicochemical Information
|
| Linearity of Dilution | Minimum of 10 samples spiked and diluted (at least 3 dilutions) with acceptable recovery between 80-120%. |
| Product Usage Statements
|
| Usage Statement |
- Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
|
| Packaging Information
|
| Material Size | 96 well assay |