millipore,密理博,LC0HCG6S2,Millistak+ Lenticular Disc Filters, C0HC media series, 16 in. diameter, 8-cell, silicone seal, 2/pack

产品名称:
Millistak+ Lenticular Disc Filters, C0HC media series, 16 in. diameter, 8-cell, silicone seal, 2/pack
产品型号:
LC0HCG6S2
产品描述:

产品介绍

millipore,密理博,LC0HCG6S2,Millistak+ Lenticular Disc Filters, C0HC media series, 16 in. diameter, 8-cell, silicone seal, 2/pack
millipore,密理博,LC0HCG6S2,Millistak+ Lenticular Disc Filters, C0HC media series, 16 in. diameter, 8-cell, silicone seal, 2/pack

重要规格表

Description
Catalogue NumberLC0HCG6S2
Trade Name
  • Millistak+®
DescriptionMillistak+® Lenticular Disc Filters, C0HC media series, 16 in. diameter, 8-cell, silicone seal, 2/pack
Product Information
Device ConfigurationStack Disk
Filter GradeDE30 / DE60
Maximum Differential Pressure, bar (psid)Forward: 2.07 bar (30 psid) @ 25 °C; 1.03 bar (15 psid) @ 80 °C; 0.21 bar (3 psid) @ 123 °C. Reverse: 0.03 bar (0.5 psid)
Maximum Inlet Pressure, bar (psi)2.1 bar (30 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C; 0.2 bar (3 psi) @ 123 °C
Stack Design16 in. diameter, 8-cell
Quality LevelMQ300
Applications
ApplicationPerfusion bioreactor fluid
Biological Information
Bacterial EndotoxinsAqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
SanitizationMay be hot water sanitized for 20 cycles using purified water @ 80 °C for 30 minutes
SterilizationMay be steam sterilized for 3 steam-in-place (SIP) cycles of 30 minutes @ 123 °C
WettabilityHydrophilic
Physicochemical Information
Product Water Conductivity at 25°C5 – 7 umho/cm after a pure water flush of 10 L/ft2 (100 L/m2) of media surface area per autoclaved (1 cycle of 30 minutes at 123 °C) 12" 16-stack device
Gravimetric ExtractablesPost autoclave (1 cycle of 30 minutes at 123 °C) and pure water flush of 100 L/m2 (10 L/ft2) of media surface area.
NVR: 1.50 – 2.02 mg/m2
TOC: 416– 593 ppb
Dimensions
Diameter40.64 cm (16 in.)
Filtration Area1.8 m²
Materials Information
Chemistry
  • Cellulose (CL)
  • Inorganic Filter Aid
  • Mixed Cellulose Esters (MCE)
Device Material
  • Polypropylene
Seal MaterialSilicone (SI)
Packaging Information
Material Size2
Specifications
Oxidizable SubstancesThe effluent of an autoclaved (1 cycle of 30 minutes @ 123 °C) stacked device is negative after a WFI flush of 10 liters per ft2 (100 L/m2) of media surface area
TOC565–1037 ppb post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 10 liters per ft2 (100 L/m2) of media surface area