millipore,
密理博,122641,ProteoExtract Albumin Removal Kit, Maxi
| Description
|
| Overview | High capacity, reusable columns specifically designed for the rapid and efficient removal of >80% of albumin from body fluid samples, either on an LC-instrument or manually (attached to a syringe). Removal of these high abundance proteins allows enhanced detection of low abundance proteins. Each column can be re-used up to 10 times. |
| Catalogue Number | 122641 |
| Brand Family |
Calbiochem®
|
| Materials Required but Not Delivered | • Micropipettes and tips, 10 µl, 200 µl and 1 ml size • Syringes for manual usage. • High quality water (resistance > 18 mΩ) • Sample collection tubes e.g. 15 ml-centrifuge tubes |
| Product Information
|
| Form | 20 Samples (60-180 µl each) |
| Format | Affinity column |
| Kit contains | Two Albumin Removal Columns, 10X Albumin/IgG Binding Buffer, Albumin Elution Buffer, and a user protocol. |
| Biological Information
|
| Sample Type | Serum, plasma, CSF |
| Product Usage Statements
|
| Intended use | The ProteoExtract® Albumin Removal Kit (Maxi) provides a convenient, reproducible and highly specific method for removing serum albumin from 90 to 180 µl of plasma or serum. The kit provides columns containing a novel albumin-specific affinity resin. These columns allow for the removal of more than 80 % of serum albumin from human body fluid samples when used according to the instructions provided in this manual. The column hardware is designed to allow for both manual and LC-instrument controlled usage. When used manually, the albumin removal columns are operated as syringe-tip filters, when used with LC-instrument control, the columns can be connected to any standard HPLC/FPLC instrument via a 10/32" port using the provided adapters. For guidelines of ProteoExtract® column connections and operation, please refer to section 3 of this manual. |
| Storage and Shipping Information
|
| Ship Code |
Blue Ice Only
|
| Toxicity |
Multiple Toxicity Values, refer to MSDS
|
| Hazardous Materials Attention: |
Due to the nature of the Hazardous Materials in this shipment, additional shipping charges may be applied to your order. Certain sizes may be exempt from the additional hazardous materials shipping charges.
|
| Storage |
+2°C to +8°C
|
| Storage Conditions | Upon arrival store entire kit contents at 4°C. Avoid freezing of the Albumin Removal columns! Freezing thawing will destroy the affinity resin and the columns no longer function. |
| Do not freeze |
Yes
|
| Supplemental Information
|
| Kit contains | Two Albumin Removal Columns, 10X Albumin/IgG Binding Buffer, Albumin Elution Buffer, and a user protocol. |