密理博,03-0153-00,SMC Glucagon High Sensitivity Immunoassay Kit
重要规格表
| Key Applications |
| Single Molecule Counting (SMC™)
|
| Description
|
| Catalogue Number | 03-0153-00 |
| Trade Name |
|
| Description | SMC™ Glucagon High Sensitivity Immunoassay Kit |
| Overview | The SMC™ Glucagon High Sensitivity Immunoassay Kit contains all reagents required to perform the assay. This assay takes advantage of a standard immunoassay workflow configured in a standard plate format. Assay protocols are similar to existing sandwich ELISA methods with two key differences: 1) Elution buffer disrupts the sandwich, separating the labeled detection antibody for quantification. 2) The Erenna® and SMCxPRO™ immunoassay systems detect analytes using Single Molecule Counting (SMC™) technology. |
| Background Information | Glucagon is the most important counter-regulatory hormone to insulin in blood glucose homeostasis. It elevates blood glucose levels by stimulating gluconeogenesis and glycogenolysis while inhibiting glycogenesis and gylcolysis in the liver. This hormone is extremely important in studying therapeutic targets for diabetes, particularly Type I. |
| Product Information
|
| Components |
- Standard Diluent
- Glucagon Standard
- Assay Buffer
- Glucagon Beads
- Glucagon Detection
- 10X Wash Buffer
- Buffer D
- Elution Buffer B
|
| Precision, % |
- Intra-assay CV% average (n=20): <10%
- Inter-assay CV% average (n=6): <15%
|
| Applications
|
| Application | The sensitivity of the Single Molecule Counting (SMC™) technology gives the SMC™ Glucagon High Sensitivity Immunoassay Kit unparalleled performance in the quantification of Glucagon in human, mouse and rat plasma. |
| Key Applications |
- Single Molecule Counting (SMC™)
|
| Biological Information
|
| Cross Reactivity | No significant cross-reactivity to related proteins was observed (<0.5% to human Oxyntomodulin and 0% to human GLP-1, GLP-2, and GIP). |
| Accuracy |
- Minimum of 5 samples spiked with acceptable recovery between 80-120%.
|
| Physicochemical Information
|
| Sensitivity |
- Lower Limit of Quantification: 0.781 pg/mL
|
| Product Usage Statements
|
| Usage Statement |
- Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
|
| Packaging Information
|
| Material Size | 96 well assay |